LM2554-0

LM2554-0
Bel Power (Melcher) M-Series 50W railway AC/DC power supply
  • Class I equipment
  • Input over- and undervoltage lockout
  • Adjustable output voltages with remote on/off
  • Emissions according to EN 55011/55032
  • Very high reliability
Article numberLM2554-0
Available stock6
ManufacturerBel Power (Melcher)
TypeAC/DC
Input Voltage85 – 264VAC
Output voltage15V
Output current1.7A
Output voltage 215V
Output current 21.7A
Total power50W
Peak power69W
Op. temperature-25 / +71°C
Size169×38.7x111mm
Weight770g
Efficiency80%
FormfactorCasette
ApplicationRailway
SpecialsEN55011 / EN45545

The M Series of DC-DC and AC-DC converters represents a broad and flexible range of power supplies for use in advanced industrial electronic systems. Features include high efficiency, reliability, low output voltage noise and excellent dynamic response to load/line changes due to individual regulation of each output.
The converter inputs are protected against surges and transients occurring at the source lines. An input over- and undervoltage lockout circuit disables the outputs, if the input voltage is outside the specified range. An inrush current limitation prevents circuit breakers and fuses from tripping at switch-on.
All outputs are open- and short-circuit proof, and are protected against overvoltages by means of built-in suppressor diodes. The outputs can be inhibited by a logic signal applied to the connector (pin 2). If the inhibit function is not used, pin 2 should be connected to pin 23 to enable the outputs.
LED indicators display the status of the converter and allow visual monitoring of the system at any time.
Full input to output, input to case, output to case, and output to output isolation is provided.
The case design allows operation at nominal load up to 71 °C in a free-air ambient temperature. If forced cooling is provided, the ambient temperature may exceed 71 °C but the case temperature should remain below 95 °C under all conditions.
A temperature sensor generates an inhibit signal, which disables the outputs, when the case temperature TC exceeds the limit. The outputs automatically recover, when the temperature drops below the limit.
The converters may either be plugged into a 19” rack system according to IEC 60927-3 or be mounted onto a chassis or a plate.

Contact

Im Spitz 7
8330 Pfäffikon ZH
Schweiz